| Item ID |
391374
|
| Manufacturer |
Agilent
|
| Model |
G1314A-G1311A-G1379A-G1316A
|
| Part Number |
|
| Description |
1100 Series HPLC ChemStation System
|
| Made In |
Japan
|
| Weight |
180 lbs
|
| Manual |
-
|
| Condition |
Tested
|
| Cosmetic |
Excellent
|
| Qty Available |
1
|
|
Description
This HPLC ChemStation System includes
- HP/Agilent 1100 Series Variable Wavelenght Detector (VWD) model G1314A
- HP/Agilent 1100 Series Quaternary Pump model G1311A
- HP/Agilent 1100 Series 4-channel Micro-Vacuum Degasser model G1379A
- HP/Agilent 1100 Series Thermostatted Column Compartment model G1316A
- Manual Injector - Software - Computer - Manual
G1314A Specifications
Detector Type: Bouble-Beam Photometer
Light Source: Deuterium Lamp
Wavelenght Range: 190-600nm
Wavelenght Accuracy: ±1nm
Bandwidth: 6.5 nm Typical
Communication Ports: CAN, GPIB, RS-232C, APG Remote, Ethernet LAN Option
G1311A Specifications
Settable Flow Range: 0.001 - 10 mL/min in 0.001 mL/min Increments
Flow Range: 0.2 - 10 mL/min
Communication Ports: CAN, GPIB, RS-232C, APG Remote
G1379A Specifications
Bottle Head Assembly, Solvent Cabinet, Inlet/Outlet Tube
Maximum Flow Rate: 0-10 mL/min per channel, 5-10 mL/min at reduced Degausing Performance
Number of channels: 4
Internal Volume: Typically 1mL per channel
pH Range: 1-14
Analog output: for pressure monitoring, range 0-3 V
G1316A Specifications
Temperature Range: 10° below ambient to 80°C
Temperature Stability: +/- 0.15°C
Temperature Accuracy: +/- 0.8°C
Column Capacity: Three 30 cm columns
Warm-up/Cool0down: 5 minutes from ambiant to 40°C
Communication Ports: CAN, GPIB, RS-232C, APG Remote
Manual Injector Specifications
Mounting Pole Connection Capillary: 0.17mm id-500mm
Base Plate Organizer Plate Carch Tube Cap
Valve syringe Fixed Needle 50uL
Computer Specifications
Prosys: Windows XP Professional
HP Registered
Intel Pentium 4 3.20GHz, 504Mb RAM
Model WEB-BTO-INTEL-P
ViewSonic E70 Monitor
Mouse, Keyboard
Software Included
- Agilent G2175AA rev. A-10-01 Chemstation Software
- Agilent Chemstation Plus User Documentation rev.A.09.xx
- Agilent 1100 Series HPLC Maintenance and repair
- Agilent G1369A Lan Card rev.A-01-02
Manuals Included
- Agilent Qualification Wookbook
- Agilent Understanding you Chemstation
- Agilent G2090 Chemstation gor GC System
- Agilent Chemstation for CE Systems
- Agilent Chemstation for LC 3D Systems
- Agilent Getting Started
- Agilent G2070 Installing your A/D Chemstation
- Agilent Installing your Chemstation
- Agilent G2070 Installation
- Agilent 1100 Series LC/MSD Quick Start Guide
- Agilent G1956 LC/MSD System Installation Guide
Also Included
- All Interconnecting Cables
- 50uL FN LC Syringe
- Micropak 15 cm x 4 mm Column
|